Product | Description |
HM0667 |
Single interface quantum well |
| Growth Sheet |
|
| PF_11-14-12.1-growth |
|
| PF_11-14-12.1 |
|
PF 01_05_04_1 |
Pulsing, Hole doped |
| Growth Sheet |
|
PF 06_21_05.2 |
Pulsing, Hole doped, as per 05_02_05.1 but 20% thicker barrier |
| Growth Sheet |
|
PF 05_15_00.1 |
Albert Wang, Schottky Gate, 70A well, 800A deep, 34A barrier. Modeled on 09-28-92.7 |
| Design Sheet |
|
| Growth Sheet |
|
PF 01_20_04.1 ? |
Design sheet says "Albert Wang, Incomplete" |
| Design Sheet |
|
PF 03_17_98.1 |
Pulsing sample, 100 hz. 175A well, 147A barrier. |
| Design Sheet |
|
PF 04_02_97 |
Pulsing sample, 75 hz, 175A well, 193A supperlattice tunnel barrier. |
| Design Sheet |
|
canadian pharmacies |
highest rated canadian pharmacies |
| Design Sheet |
|
| Growth Sheet |
|
PF 04_17_91 |
Albert Wang, Schottky Gate, 150A quantum well, 800A deep, 85A Superlattice Tunnel |
| Design Sheet |
|
PF 05_02_05.1 |
Pulsing, Hole Sample "Thicker Barrier, Heavier Doping" |
| Growth Sheet |
|
PF 06_15_01.1 |
Albert Wang, Repeat of Ashoori: 10_17_92.1 . 800A deep well, 175A wide, 80A superlattice tunnel barrier. Schottky Gate |
| Design Sheet |
|
| Image |
|
| Image |
|
| Image |
|
| Image |
|
| Image |
|
| Image |
|
| Image |
|
| Growth Sheet |
|
PF 06_19_98.1 |
Pulsing Sample, 1khz, 175A well |
| Design Sheet |
|
| Growth Sheet |
|
PF 06_19_98.2 |
Pulsing Sample, 10khz |
| Design Sheet |
|
PF 09_25_96 |
Pulsing Sample 27 khz. |
| Design Sheet |
|
PF 10_09_03.1 |
Hole doped. Carbon source broke ; no doping. |
| Design Sheet |
|
| Image |
|
| Image |
|
| Image |
|
| Image |
|
| Growth Sheet |
|
PF 10_12_92 |
Albert Wang, Schottky Gate, 800A deep, 175A quantum well, 80A superlattice tunnel. Is this perhaps actually 10-17-92? |
| Design Sheet |
|
PF 10_20_03.1 |
Schottky Gate, 34A barrier, 140A well, 700A deep. Hole Doped. (carbon). Electrode is 2x10^18 |
| Design Sheet |
|
| Growth Sheet |
|
PF 10_29_01.2 |
Albert Wang. Doped cap dot, 175A well, 57A tunnel barrier. |
| Design Sheet |
|
| Image |
|
| Image |
|
| Growth Sheet |
|
PF 12_15_04.1 |
Hole sample with thicker barrier |
| Growth Sheet |
|
PF 06_06_07.2 |
Pulsing, based on 6-19-98.1 w/ 230A quantum well and 600A blocking barrier. |
| Growth Sheet |
|
PF 04-18-05.2 |
Scanning electron sample, low-density (7.5e10). Requires LED to be shined. |
| Growth sheet |
|
PF 04-18-05.1 |
Scanning electron sample, low-density (6.8e10). Requires LED to be shined. |
| Growth sheet |
|
PF 10-20-08.1 |
New hole pulsing sample; heavily doped contacts and hopefully cleaner tunnel barrier |
| PF 10-20-08.1 |
Growth sheets from Loren |
PF_5-2-11 |
Electron pulsing. Based on 6-6-07 but with faster tunnel barrier (>100 kHz) and cold bottom spacer growth. |
| PF_5-2-11_growth |
growth sheet |
PF_5-24-10 |
Hole pulsing. 140A well,10 kHz barrier, cold spacer growth. Used for all hole pulsing data. |
| PF_5-24-10_growth |
growth sheet |
PF_11-14-12.1 |
Electron tunnel sample. 125A tunnel barrier on the bottom, 230A QW. |
| PF_11-14-12.1-growth |
|